China Oil Exploration 20mA Electric Meter Checking Device RS232 for sale
China Oil Exploration 20mA Electric Meter Checking Device RS232 for sale
China Oil Exploration 20mA Electric Meter Checking Device RS232 for sale
China Oil Exploration 20mA Electric Meter Checking Device RS232 for sale
China Oil Exploration 20mA Electric Meter Checking Device RS232 for sale
China Oil Exploration 20mA Electric Meter Checking Device RS232 for sale

Oil Exploration 20mA Electric Meter Checking Device RS232

electric meter testing device,using in multiple palce like oil exploration,network communication,attached user's manual TECHNICAL PARAMETERS Electrical parameters  Accuracy 0.05%, 0.1%, 0.2% Power supply 220V ± 10% or 110V ± 10%, 50/60Hz ± 2Hz Test Voltage  Range 0V-600V Error ±0.05% (30V-600V) ±0.1% (5V-30V) Harmonic 2nd-63st Test Current  Range (direct connection) 20mA-20A Error (direct connection) ±0.05% (100mA-20A) ±0.1% (20mA-100mA) Range (Clamp CT) 10mA-3000A Error

Place of Origin BEIJING,CHINA
Packaging Details CARTON
test voltage range 0V-600V
communication port RS232
accuracy 0.05%, 0.1%, 0.2%
weight 3KG
Product Description

electric meter testing device,using in multiple palce like oil exploration,network communication,attached user's manual

 

TECHNICAL PARAMETERS

Electrical parameters 
Accuracy 0.05%, 0.1%, 0.2%
Power supply 220V ± 10% or 110V ± 10%, 50/60Hz ± 2Hz
Test Voltage 
Range 0V-600V
Error ±0.05% (30V-600V)
±0.1% (5V-30V)
Harmonic 2nd-63st
Test Current 
Range (direct connection) 20mA-20A
Error (direct connection) ±0.05% (100mA-20A)
±0.1% (20mA-100mA)
Range (Clamp CT) 10mA-3000A
Error (Clamp CT) ±0.2% (100mA-3000A)
±0.5% (10mA-100mA)
Harmonic 2nd-63st
Power measure error 
Active power (direct connection) ±0.05% (0.1A-20A)
±0.1% (0.02A-0.1A)
Reactive power (direct connection) ±0.1% (0.1A-20A)
Energy measure error 
Active energy (direct connection) ±0.05% (0.1A-20A)
±0.1% (0.02A-0.1A)
Reactive energy (direct connection) ±0.1% (0.1A-20A)
Phase angle 
Range 0° ~ 360°
Resolution 0.01°
Error ±0.05°
Frequency 
Range 45Hz-65Hz
Resolution 0.001Hz
Accuracy 0.005Hz
Power factor 
Range -1 ~ 0 ~ 1
Resolution 0.0001
Error 0. 0005
Pulse output  
Energy constant 180000imp/kWh, 1800imp/kWh, 18imp/kWh
Pulse ratio 1:1
Output level 5V
Pulse input 
Input channel 1
Input level 5-24V
Input frequency Max. 2MHz
Display 
Resolution 6”TFT (640×480)
Function 
Vector diagram Yes
Waveform Yes
Energy accumulation Yes
Communication port RS232
Communication with PC Yes
Mechanical parameters 
Dimensions (W×H×D) (mm) 390×200×160
Host Weight (mm) 3
Weight (including Accessories 3pcs 100A clamp CT) (kg) 12
Environmental conditions 
Ambient temperature -10°C to 40°C
Relative humidity 30%-85%
Interested in this product?