RVVP Shield Flexible Power Electrical Cable Switch Control
RVVP Shield Flexible Power Electrical Cable Wire Environmental Protection Application In dry rooms ,apparatus switch and distribution boards,for fixed installation in conduits,over and under plaster and on insulated supports over plaster,direct laying in plaster is not permitted Specifications RVP,RVP-105 300/300V Nominal area of conductor No./Dia. Of Conductor Max.O.D Approx.Weight Max. D.C Resistance of Conductor (20 ℃)Ω /km mm2 mm mm2 kg/km Ω /km 0.20 12/0.15 2.2 8.3 92.3
RVVP Shield Flexible Power Electrical Cable Wire Environmental Protection
Application
In dry rooms ,apparatus switch and distribution boards,for fixed installation in conduits,over and under plaster and on insulated supports over plaster,direct laying in plaster is not permitted
Specifications
RVP,RVP-105 300/300V
| Nominal area of conductor | No./Dia. Of Conductor | Max.O.D | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃)Ω /km |
| mm2 | mm | mm2 | kg/km | Ω /km |
| 0.20 | 12/0.15 | 2.2 | 8.3 | 92.3 |
| 0.30 | 16/0.15 | 2.6 | 10.5 | 69.2 |
| 0.40 | 23/0.15 | 3.0 | 15.9 | 48.2 |
| 0.50 | 16/0.20 | 3.1 | 16.8 | 39.0 |
| 0.75 | 24/0.20 | 3.4 | 20.9 | 26.0 |
| 1.0 | 32/0.20 | 3.8 | 26.5 | 19.5 |
| 1.5 | 30/0.25 | 4.1 | 32.4 | 13.3 |
| 2.5 | 49/0.25 | 4.9 | 48.2 | 7.98 |
RVP,RVP-90 300/300V 2-CORE ELLIPSE MODEL
| Nominal area of conductor | No./Dia. Of Conductor | Max.O.D | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃)Ω /km |
| mm2 | mm | mm2 | kg/km | Ω /km |
| 2X0.20 | 2X12/0.15 | 2.2X3.9 | 14.7 | 92.3 |
| 2X0.30 | 2X16/0.15 | 2.8X4.8 | 19.7 | 69.2 |
| 2X0.40 | 2X23/0.15 | 3.0X5.2 | 28.1 | 48.2 |
| 2X0.50 | 2X16/0.20 | 3.1X5.4 | 29.9 | 39.0 |
RVP,RVP-90 300/300V 2-CORE ELLIPSE MODEL
| Nominal area of conductor | No./Dia. Of Conductor | Max.O.D | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃)Ω /km |
| mm2 | mm | mm2 | kg/km | Ω /km |
| 2X0.75 | 2X24/0.20 | 3.4X6.0 | 37.5 | 26.0 |
| 2X1.0 | 2X32/0.20 | 3.8X6.8 | 48.6 | 19.5 |
| 2X1.5 | 2X30/0.25 | 4.1X7.4 | 59.9 | 13.3 |
RVVP,RVVP1 300/300V 2-CORE
| Nominal area of conductor | No./Dia. Of Conductor | Max.O.D | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃)Ω /km |
| mm2 | mm | mm2 | kg/km | Ω /km |
| 2X0.20 | 2X12/0.15 | 5.3 | 33.2 | 92.3 |
| 2X0.30 | 2X16/0.15 | 6.2 | 49.3 | 69.2 |
| 2X0.40 | 2X23/0.15 | 6.6 | 57.0 | 48.2 |
| 2X0.50 | 2X16/0.20 | 6.8 | 59.2 | 39.0 |
| 2X0.75 | 2X24/0.20 | 7.4 | 70.7 | 26.0 |
| 2X1.0 | 2X32/0.20 | 8.2 | 86.7 | 19.5 |
| 2X1.5 | 2X30/0.25 | 9.2 | 110.4 | 13.3 |
RVVP,RVVP1 300/300V 3-CORE
| Nominal area of conductor | No./Dia. Of Conductor | Max.O.D | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃)Ω /km |
| mm2 | mm | mm2 | kg/km | Ω /km |
| 3X0.20 | 3X12/0.15 | 5.8 | 38.6 | 92.3 |
| 3X0.30 | 3X16/0.15 | 6.5 | 48.6 | 69.2 |
| 3X0.40 | 3X23/0.15 | 6.9 | 56.7 | 48.2 |
| 3X0.50 | 3X16/0.20 | 7.1 | 60.7 | 39.0 |
| 3X0.75 | 3X24/0.20 | 7.8 | 73.6 | 26.0 |
| 3X1.0 | 3X32/0.20 | 9.1 | 100 | 19.5 |
| 3X1.5 | 3X30/0.25 | 10.1 | 131 | 13.3 |
| 4X0.20 | 4X12/0.15 | 6.2 | 45.9 | 92.3 |
| 4X0.30 | 4X16/0.15 | 7.0 | 57.5 | 69.2 |
| 4X0.40 | 4X23/0.15 | 7.5 | 67.9 | 48.2 |
RVVP,RVVP1 300/300V 3-CORE
| Nominal area of conductor | No./Dia. Of Conductor | Max.O.D | Approx.Weight | Max. D.C Resistance of Conductor (20 ℃)Ω /km |
| mm2 | mm | mm2 | kg/km | Ω /km |
| 5X0.20 | 5x12/0.15 | 6.7 | 52.7 | 92.3 |
| 5X0.30 | 5x16/0.15 | 7.6 | 66.6 | 69.2 |
| 5X0.40 | 5x23/0.15 | 8.1 | 78.8 | 48.2 |
| 6x0.20 | 6x12/0.15 | 7.2 | 59.6 | 92.3 |
| 6x0.30 | 6x16/0.15 | 8.2 | 76.6 | 69.2 |
| 6x0.40 | 6x23/0.15 | 9.2 | 98.3 | 48.2 |
| 7x0.20 | 7x12/0.15 | 7.2 | 64.2 | 92.3 |
| 7x0.30 | 7x16/0.15 | 8.2 | 82.3 | 69.2 |
| 7x0.40 | 7x23/0.15 | 9.2 | 106.0 | 48.2 |
| 10x0.20 | 10x12/0.15 | 9.3 | 94.3 | 92.3 |
| 10x0.30 | 10x16/0.15 | 10.9 | 132.0 | 69.2 |
| 10x0.40 | 10x23/0.15 | 11.6 | 157.0 | 48.2 |
| 12x0.20 | 12x12/0.15 | 9.6 | 105 | 92.3 |
| 12x0.30 | 12x16/0.15 | 11.2 | 147 | 69.2 |
| 12x0.40 | 12x23/0.15 | 11.9 | 175 | 48.2 |