High-precision elevator load weighting device with 5kg sensitivity and ≤1.5% system error. Supports 500-20000kg payload, DC 24V power, and full-load/overload switching output. Includes 1-year warranty and free replacement for quality defects.

Place of Origin China
Keywords Load cell
Original place China
Packaging Details 1 in box,50 boxes in a carton
Power supply AC/DC 24V
Model Number EWD-RL-J2
Product Description

Elevator load weighting device/ elevator parts load cell EWD-RL-J2



System Introduction

Main Features:

 

Application Range

Being applicable to all elevators with payload of 500㎏~20000㎏ for full-load and overload signal(Depending on loading sensor with the options of 1.5tons/3T/5T)

Sensitivity

For the elevator with rated load of 1 ton, it is 5Kg

System Error

≤1.5%(5~40℃)

Output Mode

Switching Signal:Full-load and overload Dynamic Close and Dynamic Open contact

Operation Temperature

-25~55℃

Power Source

DC 24V(±10%),Operating current for the whole set≤100mA


Intensity exceeding the above listed parameter limits may cause the system abnormality or its permanent damage.



Product Appearance, Installing Method and Relevant Structure



<!--[endif]--><!--[endif]-->

Installation method of the type A sensor:
 


Installation method of the type D sensor:

System Adjustment:

Description of Other Indication States:

 

Display Code

Implication

Solution

1

FY

System Startup

2

PC

Sensor Resetting

3

PP

Get into the status of operation parameters modification

4

Lo

Ready for Autotuning Operation

5

PL

No payload is detected by sensor

(Static Displaying represents preparative status,twinkling displaying for the end of testing

6

PH

Exceeding the measuring range of maximum load

7

EL

Saved

Check the cable of the sensor, system power and payload

8

EH

Saving Failure

9

Pan

Saved

 

10

EA

Saving Failure

Remodify the operation parameters

After system commissioning, press and hold 【◎】 in normal operation,〖J1〗/〖J2〗will flicker alternately,at this time, J1/J2 output alternately.

Autotuning operation for Separate items:(Use: It is in need to individually autotune no-load or rated load for a well-adjusted system separately)


Promise:

<!--[if !supportLists]-->1. <!--[endif]-->If this system appears any quality problem of product itself in 1 year after delivery, it will be replaced freely(damage of the product seal will not be dealt with).

<!--[if !supportLists]-->2. <!--[endif]-->Any system abnormality in adjustment or operation, please contact our company directly.

  •  

Packing List

Controller of EWD-RL-J2 Elevator Loading Device

1

Type EWD-GDH: sensor and its accessories

1Set

Screw Sets M4 X 40

2 Sets

System Instruction Manual

1 Copy

 




 

EWD-H-XJ3 Elevator parts load weighting device ,load cellEWD-H-XJ3 Elevator parts load weighting device ,load cellEWD-H-XJ3 Elevator parts load weighting device ,load cell

 

Website:www.estlift.com/www.est-lift.com

Contact Person:Miss Yolly

E-mail:[email protected]

[email protected]

Skype:yollyapple

Wechat:YollyApple

Whatsapp&Mobile:+86 189 9286 2361

Tel:+86-029 8841 6613-808

Fax:+86-029 8556 5714-886

Interested in this product?
Contact us now for more details and a custom quote.