High Precision Ceramic Single Crystal Composite Wafer for NDT Sensor Application
High Precision Ceramic Single Crystal Composite Wafer for NDT Sensor Application Performance Features High sensitivity High bandwidth Low acoustic impedance Good matching with water / human tissue / tested medium Low ringing time High signal-to-noise ratio 1 Type 1-3 ceramic composite wafers Example: Frequency MHz/ Length × width mm Overall dimensions Wafer length L(mm) Default tolerance±0.05mm Note: The single crystal composite frequency is 5-10 MHZ, and the ceramic
Composite method
Type 1-3 composite
Place of Origin
China
Packaging Details
Outer carton packaging
ceramic composite frequency
0.5-15 MHZ
Base material model
PZ44
Supply Ability
10 Sets/Month
Product Description
High Precision Ceramic Single Crystal Composite Wafer for NDT Sensor Application
Performance Features
- High sensitivity
- High bandwidth
- Low acoustic impedance
- Good matching with water / human tissue / tested medium
- Low ringing time
- High signal-to-noise ratio
| 1 | Type 1-3 ceramic composite wafers | Example: Frequency MHz/ Length × width mm | ||||
| Overall dimensions | ||||||
| Wafer length L(mm) | Default tolerance±0.05mm | Note: The single crystal composite frequency is 5-10 MHZ, and the ceramic composite frequency is 0.5-15 MHZ. Other frequencies require technical confirmation |
||||
| Wafer width W(mm) | Default tolerance±0.05mm | |||||
| Wafer thickness H(mm)/ wafer frequency(MHz) | Default tolerance for thickness±0.005mm | |||||
| pitch(mm) | (The size of the small crystal column is added with a knife slit) | It would be best if the customer could provide it. Some Osos have default Settings | ||||
| Knife slit(mm) | ||||||
| Performance parameters | ||||||
| Composite method | Type 1-3 composite | |||||
| Base material model | PZ44 | |||||
| Process requirements | ||||||
| Does the electrode need to be edge-wrapped | When edge banding is required, chamfering will be done by default. The drawings provided by the customer are attached | |||||
| Is an isolation slot needed | When an isolation tank is required, the customer shall provide the drawings (including dimensions and polarity) as attached | |||||
| Coating requirements | PVD:Gilding | |||||
| Whether polarization is needed | Default polarization | |||||
| Whether the positive and negative poles are marked | By default, the red marker dot is the positive pole | |||||
| Other special requirements | Please describe it in detail if necessary | |||||
| Test report | ||||||
| ULSO LOGO report | √ | |||||
| Logo-free report | ||||||
| Packaging requirements | ||||||
| Independent packaging | √ | |||||
| Not packaged independently | ||||||
Application
- Ultrasonic flaw detection NDT probe
- Medical ultrasound transducer
- Underwater acoustic transducer
- Phased array probe
- High frequency ultrasonic sensor