320mm Sheave Elevator Traction Machine With Wire Ropes
Sheave Φ320mm Elevator Traction Machine With Elevator Wire Ropes Rated Voltage :AC380V Brake Voltage :DC110V Weight :200kg Max. Static Load :3000kg Roping :2:1 Wrap :Single Insulation :F Protection :IP41 Traveling Height ≤Rated Speed×60 ELEVATOR TRACTION MACHINE(ROPING 2:1) Load(kg) Speed(m/s) Rated output(kw) Current(A) Rated speed(rpm) Frequency(Hz) Sheave diameter(mm) Poles(2p) Torque(N.m) Ropes Groove 320 0.5 1.1 3 60 9.9 320 20 170 4x Ø 8x12 Undercut U 320 1.0 2.1 5 119
Sheave Φ320mm Elevator Traction Machine With Elevator Wire Ropes
Rated Voltage :AC380V
| Load(kg) | Speed(m/s) | Rated output(kw) | Current(A) | Rated speed(rpm) | Frequency(Hz) | Sheave diameter(mm) | Poles(2p) | Torque(N.m) | Ropes | Groove |
| 320 | 0.5 | 1.1 | 3 | 60 | 9.9 | 320 | 20 | 170 | 4x Ø 8x12 | Undercut U |
| 320 | 1.0 | 2.1 | 5 | 119 | 19.9 | 320 | 20 | 170 | 4x Ø 8x12 | Undercut U |
| 400 | 0.5 | 1.3 | 4 | 60 | 9.9 | 320 | 20 | 213 | 4x Ø 8x12 | Undercut U |
| 400 | 1.0 | 2.7 | 7 | 119 | 19.9 | 320 | 20 | 213 | 4x Ø 8x12 | Undercut U |
| 450 | 0.5 | 1.5 | 4 | 60 | 9.9 | 320 | 20 | 240 | 4x Ø 8x12 | Undercut U |
| 450 | 1.0 | 3.0 | 8 | 119 | 19.9 | 320 | 20 | 240 | 4x Ø 8x12 | Undercut U |
| 450 | 1.5 | 4.5 | 13 | 179 | 29.8 | 320 | 20 | 240 | 4x Ø 8x12 | Undercut U |
| 450 | 1.6 | 4.8 | 13 | 191 | 31.8 | 320 | 20 | 240 | 4x Ø 8x12 | Undercut U |
| 450 | 1.75 | 5.2 | 13 | 209 | 34.8 | 320 | 20 | 240 | 4x Ø 8x12 | Undercut U |
DIMENSION DRAWING
Delivery
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.